Choosing a triple-extruded door seal for an electrical cabinet
A door can latch cleanly while the bulb barely touches the frame near the lock. A larger bulb might close that gap but make the hinge side bind. Start with a drawing that locates both interfaces: the edge that carries the seal and the face that compresses it.

Check the carrier on a finished edge
Measure flange thickness on the straight edge, at folds and across any overlap. Include the coating. Measure the available insertion depth from the edge to the first bend or obstruction. A carrier that fits the thickness can still bottom out early on a short flange. Seat a sample by hand and check that its gripping lips engage both faces and that the base stays seated at the corner.
Trace the door's final movement
Sketch the hinge side and the latch side separately. Mark where the door first touches the bulb and where it ends up when latched. A face that slides across a bulb before compressing it can roll the bulb sideways. To see where contact occurs, try a removable transfer medium on a sample and close the door normally. Test the medium on an inconspicuous area of the finish first.
Map the smallest and largest closed gaps
Mark the hinges, latch, middle of the top edge and tightest corner on a drawing. Measure the latched gap from the same reference surface at each point. Keep both extremes in the record. Test whether the bulb maintains contact at the widest gap and whether the door closes within the specified operating force at the narrowest. Use both observations when reviewing a change to bulb position or section.