How to size U-channel edge trim to a finished panel
A width copied from a drawing can refer to the outside of the trim or to the edge it grips. Huaxuan's 20ZST sample is 7 mm wide and 10 mm high outside, with an 8 mm channel depth and a stated panel range of 1–2 mm. Each dimension answers a different fitting question.

Locate every change in edge thickness
Measure where the gripping lips will actually sit. Mark readings for a straight single skin, a folded hem and any overlapping sheets on a sketch. If the first trial uses an uncoated offcut, reserve a production-finished panel for confirmation. Include any raised weld or local thickening in the drawing so the reviewer can locate it.
Check insertion depth and external clearance
Measure inwards from the edge to the first fold, stiffener or nearby fastener. The 20ZST drawing gives an 8 mm channel depth. During trial fitting, check where the edge seats and whether the lips engage on both faces. Use the outside dimensions separately to check clearance past a moving door or drawer throughout its travel.
Fit the tightest bend before approving the straight run
Install a sample on a panel with the production corner and bend it in the intended direction. Mark the corner, the end and a thin section. Look for a lifted outer edge, bunching on the inside or movement at the end. If a straight length fits but the bend walks off, send the bend direction and radius with a photograph of the fitted sample.